EVI Heating y pompa de calor de enfriamiento
Paramater técnico:
MODELO | KFXFC-009SEI | KFXFC-014SI | KFXFC-018SI | KFXFC-020UII | DKFXFC-032UII | ||
Temporeros ambiente. gama | ℃ | -30~+43 | -30~+43 | -30~+43 | -30~+43 | -30~+43 | |
Fuente de alimentación | / | 220V 1N~50Hz | 220V 1N~50Hz | 220V 1N~50Hz | 380V 3N~50Hz | 380V 3N~50Hz | |
Grado de la prueba de la descarga eléctrica | / | Clase I | Clase I | Clase I | Clase I | Clase I | |
Grado de la protección | / | IPX4 | IPX4 | IPX4 | IPX4 | IPX4 | |
Capacity/COP de enfriamiento | Kilovatio | 7.3/2.8 | 12.0/3.0 | 14.5/2.6 | 27.0/2.8 | 27.0/2.8 | |
Calefacción a baja temperatura (A-12W41) /COP | Kilovatio | 5.1/2.2 | 9.2/2.4 | 11.0/2.3 | 20.0/2.3 | 20.0/2.3 | |
Calefacción normal de la temperatura (A7W45) /COP | Kilovatio | 8.8/3.3 | 14.4/3.7 | 18.4/3.6 | 32.0/3.6 | 32.0/3.6 | |
POLI | A7W35а/COP | Kilovatio | 9.4/4.1 | 14.5/4.5 | 18.5/4.3 | 33.0/4.3 | 33.0/4.3 |
A-7W45/COP | Kilovatio | 5.8/2.3 | 9.4/2.6 | 13.1/2.6 | 23.5/2.3 | 23.5/2.6 | |
A-15W45/COP | Kilovatio | 4.5/2.2 | 8.0/2.2 | 10.2/2.1 | 19.5/2.2 | 19.5/2.2 | |
A-20W45/COP | Kilovatio | 4.2/1.9 | 6.5/1.9 | 8.6/2.0 | 16.5/2.0 | 16.5/2.0 | |
Energía de entrada de enfriamiento clasificada | Kilovatio | 2,61 | 4 | 5,6 | 9,6 | 9,6 | |
Energía de entrada de calefacción de la baja temperatura | Kilovatio | 2,32 | 3,83 | 4,8 | 8,7 | 8,7 | |
Corriente de trabajo máxima | 20 | 32 | 40 | 25 | 25 | ||
Compresor | Tipo | / | Voluta | Voluta | Voluta | Voluta | Voluta |
Cantidad | PCS | 1 | 1 | 1 | 2 | 2 | |
Motor de fan | Cantidad | PCS | 1 | 2 | 2 | 2 | 2 |
Producción del agua | L./h | 1600 | 2500 | 2500 | 4600 | 4600 | |
Tipo/peso refrigerantes | - /kg | R407c/2.2 | R407c/4.5 | R407c/5.0 | R407c/7.5×2 | R407c/4.0×2 | |
Dimensión (W×D×H) | milímetro | 1087×435×901 | 1052×362×1346 | 1120×435×1355 | 1500×850×1750 | 1530×750×1370 | |
Dimensión que embala (W×D×H) | milímetro | 1230×500×1050 | 1160×540×1460 | 1230×540×1530 | 1600×950×1900 | 1650×850×1470 | |
Ruido | DB (A) | 54 | 58 | 56 | 65 | 65 | |
Peso neto | kilogramo | 70 | 140 | 172 | 350 | 350 | |
Peso bruto | kilogramo | 80 | 150 | 185 | 380 | 380 | |
Diámetro de circulación del tubo | pulgada | ” Hilo externo G1 | G1 1/4" hilo externo | ” Hilo externo G1.2 | ” Hilo externo G1.5 | ” Hilo externo G1.5 |
MODELO | DKFXFC-032UII | KFXFC-045UII | KFXFC-065UII | KFXFC-075UII | KFXFC-090UMII | KFXFC-150UII | KFXFC-180UMII | ||
Temporeros ambiente. gama | ℃ | -35~+43 | |||||||
Fuente de alimentación | / | 380V 3N~50Hz | |||||||
Grado de la prueba de la descarga eléctrica | / | Clase I | |||||||
Grado de la protección | / | IPX4 | |||||||
Capacity/COP de enfriamiento | Kilovatio | 27.0/2.8 | 35/3.0 | 53.0/3.0 | 65.0/3.1 | 70.0/2.8 | 130.0/2.8 | 140.0/2.8 | |
Calefacción a baja temperatura (A-12W41) /COP | Kilovatio | 20.0/2.3 | 26.0/2.3 | 37.5/2.5 | 41.0/2.5 | 55.0/2.4 | 82.0/2.5 | 110.0/2.4 | |
Calefacción normal de la temperatura (A7W45) /COP | Kilovatio | 32.0/3.6 | 43.5/3.6 | 63.0/3.9 | 73.0/3.9 | 90.0/3.6 | 146.0/3.9 | 180.0/3.6 | |
Capacidad de calefacción | A7W35а/COP | Kilovatio | 33.0/4.3 | 45.0/4.3 | 65.0/4.5 | 75.0/4.5 | 92.0/4.3 | 150.0/4.5 | 185.0/4.3 |
A-7W45/COP | Kilovatio | 23.5/2.6 | 30.5/2.6 | 41.0/2.6 | 45.0/2.6 | 62.0/2.6 | 90.0/2.6 | 122.0/2.6 | |
A-15W45/COP | Kilovatio | 19.5/2.2 | 25.0/2.2 | 34.0/2.2 | 38.0/2.2 | 50.0/2.2 | 76.0/2.2 | 100.0/2.2 | |
A-20W45/COP | Kilovatio | 16.5/2.0 | 21.0/2.0 | 30.2/2.0 | 33.0/2.0 | 43.0/2.0 | 66.0/2.0 | 86.0/2.0 | |
Energía de entrada de enfriamiento clasificada | Kilovatio | 9,6 | 11,7 | 17,7 | 21 | 25 | 46,4 | 50 | |
Energía de entrada de calefacción de la baja temperatura | Kilovatio | 8,7 | 11,3 | 15 | 16,4 | 22,9 | 32,8 | 45,8 | |
Energía de entrada normal de calefacción de la temperatura | Kilovatio | / | / | 16,2 | 18,7 | 25 | 37,4 | 50 | |
Corriente de trabajo máxima | 25 | 32 | 47 | 55 | 65 | 110 | 130 | ||
Compresor | Tipo | / | Voluta | ||||||
Cantidad | PCS | 2 | 4 | ||||||
Motor de fan | Cantidad | PCS | 2 | 4 | |||||
Temperatura del agua máxima | ℃ | 60 | |||||||
Producción del agua | L./h | 4600 | 6000 | 9100 | 11200 | 12000 | 22400 | 24100 | |
Tipo/peso refrigerantes | - /kg | R410a/4.0×2 | R410a/8.0×2 | R410a/12×2 | R410a/15×2 | R410a/15×2 | R410a/15×4 | R410a/15×4 | |
Dimensión (W×D×H) | milímetro | 1530×750×1370 | 1500×850×1750 | 2100×1100×2000 | 2100×2060×2250 | ||||
Dimensión que embala (W×D×H) | milímetro | 1650×850×1470 | 1750×950×1900 | 2260×1360×2270 | 2230×2250×2400 | ||||
Ruido | DB (A) | 65 | 65 | 68 | 68 | 68 | 69 | 69 | |
Peso neto | kilogramo | 350 | 380 | 850 | 950 | 950 | 1900 | 1900 | |
Peso bruto | kilogramo | 380 | 420 | 900 | 1000 | 1000 | 2000 | 2000 | |
Diámetro de circulación del tubo | pulgada | " Hilo externo G1.5 | " Hilo externo G1.5 | Reborde DN50 | Reborde DN50 | Reborde DN65 | Hilo externo DN65 | Hilo externo DN65 |
Diagrama de enfriamiento de la instalación del hogar heating+:
Embalaje:
![]() | ![]() |
Referencia:
País: Taiwán, China, escuela secundaria Modelo: KFXR-018 UII, KFXR-045UII Uso: Agua caliente doméstica | País: Taiwán, China, edificio residencial Modelo: KFXR-036UII, KFXR-900UII Uso: Agua caliente doméstica |
![]() | ![]() |
País: Pekín, China Modelo: KFXF-180 UII Uso: Crianza de la calefacción | País: Yunan, China Modelo: / Uso: Sequedad del áloe |
![]() | ![]() |